91 days to 18 Feb 2027

September 23, 2026

The Storage and Stationary Battery Importer's Guide to the Passport

Stationary storage sits in the industrial category, where the 2 kWh threshold decides scope and the environmental declarations arrive earlier than they do for e-bikes.

If you import home storage systems, commercial battery storage or other stationary batteries, your passport obligations look different from an e-bike importer's in two ways that matter: capacity decides whether you are in scope at all, and the environmental declarations land earlier for your category. This guide covers the storage and stationary trade specifically.

Capacity decides scope

Stationary storage falls in the industrial battery category, and the passport applies to industrial batteries with a capacity greater than 2 kWh (Art. 77(1) of Regulation (EU) 2023/1542). Unlike LMT batteries, which are caught at any capacity, here the threshold does real work.

Most residential storage products sit comfortably above 2 kWh, and commercial systems are far above it. The threshold matters at the small end of your range and for modular products. See industrial battery passport requirements, or run each model through the scope checker.

Decide what the product actually is

This is the question that causes the most confusion in storage, and it is worth settling before you collect any data. A stationary system may be sold as a complete cabinet, as stackable modules, or as modules plus a separate inverter. What you passport is what you place on the market.

Three cases:

  • A complete system sold as one unit. The system as supplied is the product, and its total capacity is what you measure against the threshold.
  • Modules sold individually, including as expansion packs. Each is a battery placed on the market in its own right, so each needs its own assessment.
  • A system assembled in the EU from imported modules. Look carefully at who places what on the market, because that determines who carries which duty.

Get this wrong and you either passport the wrong unit or misjudge the capacity threshold.

Where storage differs: the environmental declarations come sooner

For an e-bike importer, the carbon footprint and recycled content obligations are years away. For industrial batteries they are the nearest environmental requirements in the regulation, and that is the main planning difference between the two verticals.

  • Carbon footprint (Art. 7). Rechargeable industrial batteries above 2 kWh sit in the earliest wave, ahead of LMT batteries by a wide margin. The dates are structured as the later of a fixed calendar date or a set period after the Commission's methodology and format acts take effect, so the effective date follows those acts rather than sitting on a fixed day. Batteries with exclusively external storage have their own, later schedule. See the carbon footprint declaration.
  • Recycled content (Art. 8). Documentation for industrial batteries above 2 kWh begins from 18 August 2028, well ahead of the 2033 date that applies to LMT batteries, with minimum shares for cobalt, lead, lithium and nickel from 18 August 2031 and higher shares from 2036. See recycled content declaration.

The practical consequence: a storage importer cannot treat carbon footprint as a 2030s problem the way an e-bike importer reasonably can. Ask your manufacturer now whether it can produce a declaration to the Commission's method, because that capability takes time to build and it is a genuine differentiator between suppliers.

Long service life makes hosting the hard part

Stationary systems are installed for many years, often outliving the model, the warranty and sometimes the supplier relationship. The passport has to stay accurate and reachable while the battery is in service, and it ceases only once the battery has been recycled (Art. 77).

That makes hosting continuity the defining commitment in this vertical, more so than in any other. A system commissioned in 2027 may still be in a basement in 2042, and its QR code has to keep resolving. See how long a battery passport must stay online.

Two consequences worth designing for:

  1. Web addresses must be stable for decades, not product cycles.
  2. Installations change hands. Buildings are sold and operators change, so the passport has to be reachable by people who never dealt with you.

The data to collect

The Annex XIII set applies as it does elsewhere: identity and chemistry, composition, performance and durability, hazardous substances and safety, dismantling information, and the conformity evidence. See Annex XIII explained.

For storage specifically, pay attention to the performance and durability figures, which are more detailed for these products, and to the dismantling and safety information, since installers and service engineers are exactly the audience the restricted tier is meant to serve.

A working sequence

  1. Confirm capacity and the unit for every model and configuration you sell.
  2. Ask about carbon footprint capability early, since your category is in the first wave.
  3. Collect the Annex XIII data with its evidence. See what your supplier must send you.
  4. Agree marking with the manufacturer, remembering the code goes on the battery itself unless size or nature prevents it.
  5. Choose hosting for the long term, then keep the addresses fixed.

In short

Stationary storage is an industrial battery, in scope above 2 kWh, so capacity and the definition of the unit you place on the market are the first two questions. Unlike LMT batteries, the carbon footprint and recycled content obligations arrive early for this category, which makes supplier capability a live procurement issue now. And because these systems stay installed for decades, hosting continuity is the commitment to get right.